Overview
CODE | REASON | EFFECT |
Fault Code: 5689 PID: SPN: 3226 FMI: 11/11 LAMP: Amber SRT: |
Signal indicates wrong reading or sensor tampering.
|
None on performance. |
Circuit Description
The aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.
Component Location
The aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.
Conditions for Running the Diagnostics
This diagnostic runs when the aftertreatment SCR outlet temperature has been above 200°C [392° F] for a calibratable period of time while the engine is running.
Conditions for Setting the Fault Codes
The Engine Control Module (ECM) detected the power supply to the outlet NOx sensor was above or below a calibrated threshold.
Action Taken When the Fault Code is Active
- The ECM illuminates the amber CHECK ENGINE lamp and/or malfunction indicator lamp (MIL) after the diagnostic fails on two consecutive trips.
Conditions for Clearing the Fault Code
- To validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using the recommended Cummins® electronic service tool or equivalent.
- The aftertreatment SCR outlet temperature must be above 200° C [392° F] for 60 seconds before the aftertreatment outlet NOx sensor can run its internal diagnostics.
- The fault code status displayed by the recommended Cummins® electronic service tool or equivalent will change to INACTIVE immediately after the diagnostic runs and passes.
- The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
- For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
- The “Reset All Faults” command in the recommended Cummins® electronic service tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop Talk
Possible causes of this fault code include:
- Short to battery or ground in the OEM wiring harness.
Open NOx sensor power supply circuit in the OEM harness
- Incorrect system voltage set-up in the recommended Cummins® electronic service tool or equivalent.
Internal malfunction of the outlet NOx sensor
- The NOx sensor part number is incorrect.
- Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.
For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.
Troubleshooting Summary
Solution: S00000069
Verification
Conditions
- Turn keyswitch ON.
- Connect the recommended Cummins® electronic service tool or equivalent.
Action
- Use the recommended Cummins® electronic service tool or equivalent to read the fault codes.
Specification
Before troubleshooting this fault code, troubleshoot any fault code that is active or has more than one inactive count within the last 25 engine operating hours from the following list:
- Voltage: 1941
- Aftertreatment NOx: 1887, 2771, 3583, 3681, 3682, 3749, 4528, 4529, 6582
- Aftertreatment outlet oxygen: 4749
Linked Solutions
- None
Repair
- Perform a search on the appropriate fault codes.
Validation
- None
Solution: S00001008
Verification
Conditions
- Engine running.
Action
- Visually inspect for leaks in the exhaust manifold to head.
- Visually inspect for leaks from the turbocharger to exhaust manifold.
- Visually inspect for leaks in the exhaust plumbing between the turbocharger outlet and the Aftertreatment DOC intake connection.
- Visually inspect the exhaust piping for leaks, cracks, and loose connections.
- Inspect for leaks at the aftertreatment DOC housing, sensor ports and connection points.
- Visually inspect the aftertreatment and SCR components for exhaust leaks.
Specification
- If there is any damage or leaks found in the exhaust system, then proceed to the Repair section.
Linked Solutions
- None
Repair
Repair or replace only the components that were found to be out of specification.
- Replace the exhaust manifold.
- Repair or replace the exhaust plumbing.
Refer to OEM Service Manual
- Replace aftertreatment DOC.
- Replace the aftertreatment diesel particulate filter.
- Replace the aftertreatment SCR Catalyst.
Validation
- Connect all components
- Connect the recommended Cummins® electronic service tool or equivalent.
- Disable the fault code.
- Operate the engine within the “Conditions for Clearing the Fault Code” found in the Overview section of the troubleshooting procedure.
- Verify that the fault code is no longer active.
- Check ECM Calibration Revision History
- Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
- Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
- Refer to ECM Calibration Revision History Database.
Solution: S00000443
Verification
Conditions
- Connect all components.
- Turn keyswitch ON.
- Connect the recommended Cummins® electronic service tool or equivalent.
Action
- Use the recommended Cummins® electronic service tool or equivalent to read the fault codes.
- Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
- Compare the ECM code and revision number in the ECM to the calibration revision listed in the ECM calibration revision history for applicable changes.
Specification
- If a calibration update for this fault code is available, the ECM calibration revision must be that revision or higher.
Linked Solutions
- None
Repair
- Prior to downloading the ECM calibration, check to see that all job images and all other troubleshooting has been documented as downloading an ECM calibration will remove the fault codes on the ECM.
- Download the updated ECM calibration code.
Validation
- Connect all components
- Connect the recommended Cummins® electronic service tool or equivalent.
- Disable the fault code.
- Operate the engine within the “Conditions for Clearing the Fault Code” found in the Overview section of the troubleshooting procedure.
- Verify that the fault code is no longer active.
- Check ECM Calibration Revision History
- Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
- Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
- Refer to ECM Calibration Revision History Database.
Solution: S00010851
Verification
Conditions
- None
Action
- Verify all preceding solution verifications for this fault code have been performed.
Specification
- If the fault code is still active or inactive with more than one count within the last 25 engine hours and all the preceding solution verifications have been performed, then a malfunctioning aftertreatment outlet NOx sensor has been detected.
Linked Solutions
- None
Validation
- Connect all components
- Connect the recommended Cummins® electronic service tool or equivalent.
- Disable the fault code.
- Operate the engine within the “Conditions for Clearing the Fault Code” found in the Overview section of the troubleshooting procedure.
- Verify that the fault code is no longer active.
- Check ECM Calibration Revision History
- Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
- Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
- Refer to ECM Calibration Revision History Database.
If all steps have been completed and no root cause has been identified, then follow the technical escalation process.