Overview

 

CODE REASON EFFECT
Fault Code: 3749
PID: 
SPN: 3226
FMI: 2/20
LAMP: Amber
SRT: 

 

An offset in the outlet NOx sensor reading has been detected.

 

 

None on performance.

Circuit Description

The aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component Location

The aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

 

Conditions for Running the Diagnostics

This diagnostic runs when the aftertreatment SCR outlet temperature is above 200°C [392°F], and the engine is in a motoring condition.

Conditions for Setting the Fault Codes

The Engine Control Module (ECM) detected the aftertreatment outlet NOx sensor was not reading zero while in a motoring (non-fueling) condition.

Action Taken When the Fault Code is Active

  • The ECM illuminates the amber CHECK ENGINE lamp and/or malfunction indicator lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault Code

  • To validate the repair, use the recommended Cummins® electronic service tool or equivalent to perform the “Aftertreatment Outlet NOx Sensor Test” found in ECM Diagnostic Test.
  • The fault code status displayed by the recommended Cummins® electronic service tool or equivalent will change to INACTIVE immediately after the diagnostic runs and passes.
  • The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
  • For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
  • The “Reset All Faults” command in the recommended Cummins® electronic service tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

 

Shop Talk

Possible causes of this fault code include:

  • Malfunctioning aftertreatment outlet NOx sensor
  • Diesel exhaust fluid crystallization or deposits
  • Improperly installed aftertreatment outlet NOx sensor.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Solution: S00006244

Verification

Conditions

  • Turn keyswitch ON.
  • Connect the recommended Cummins® electronic service tool or equivalent.

Action

  • Use the recommended Cummins® electronic service tool or equivalent to read the fault codes.

Specification

Before troubleshooting this fault code, troubleshoot any fault code that is active or has more than one inactive count within the last 25 engine operating hours from the following list:

  • Aftertreatment NOx: 1885, 1887, 2771, 3232, 3446, 3583, 3649, 3681, 3682, 3725
  • Aftertreatment diesel exhaust fluid system: 1681, 1682, 3574, 6485, 6486
  • Ambient air temperature: 249, 256, 2398

Linked Solutions

  • None

Repair

  • Perform a search on the appropriate fault codes.

Validation

  • None

Solution: S00000540

Verification

Conditions

  • Turn keyswitch OFF.

Action

  • Verify the correct aftertreatment outlet NOx sensor is installed for engine configuration (12 or 24 volt).

Specification

  • If the aftertreatment outlet NOx sensor is not the correct sensor part number for the engine configuration, then the incorrect sensor has been installed.

Linked Solutions

  • None

Repair

  • Replace the aftertreatment outlet NOx sensor.

Refer to Procedure 019-451

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the “Conditions for Clearing the Fault Code” found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00010321

Verification

Conditions

  • Reconnect previously disconnected components.

Action

  • Perform the Aftertreatment Outlet NOx Sensor Test.

Refer to Procedure 014-036

Specification

  • If the Aftertreatment Outlet NOx Sensor Test does not pass, then proceed to the Repair section.
  • If the Aftertreatment Outlet NOx Sensor Test does not complete, then reset the Search to Aftertreatment Outlet NOx Sensor Test did not complete.

Linked Solutions

  • None

Repair

  • Replace the aftertreatment outlet NOx sensor.

Refer to Procedure 019-451

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the “Conditions for Clearing the Fault Code” found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00000967

Verification

Conditions

  • Turn keyswitch OFF.

Action

  • Perform the Aftertreatment Diesel Exhaust Fluid Doser Pump Override Test.

Refer to Procedure 011-063

Specification

  • If the Aftertreatment Diesel Exhaust Fluid Doser Pump Override Test is not within specification, then proceed to the Repair section.

Linked Solutions

  • None

Repair

  • Clean or replace the aftertreatment diesel exhaust fluid dosing valve.

Refer to Procedure 011-059

Validation

  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.
  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Operate the engine within the “Conditions for Clearing the Fault Code” found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.

Solution: S00000564

Verification

Conditions

  • Turn keyswitch OFF.

Action

  • Inspect the decomposition tube for deposits.

Refer to Procedure 011-062

Specification

  • If any excessive aftertreatment diesel exhaust fluid deposits were found inside the decomposition tube, then a plugged or restricted aftertreatment decomposition tube has been detected.
  • Proceed to Linked Solutions section for additional checks.

Linked Solutions

  • Leaks in the aftertreatment diesel exhaust fluid dosing system

Refer to S00000735

Repair

  • Clean and install the decomposition tube.

Refer to Procedure 011-062

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the “Conditions for Clearing the Fault Code” found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00000735

Verification

Conditions

  • Turn keyswitch OFF.
  • Reconnect all aftertreatment diesel exhaust fluid lines and electrical connectors to the dosing unit and aftertreatment diesel exhaust fluid tank if they have been previously disconnected during troubleshooting.

Action

  • Remove the aftertreatment diesel exhaust fluid dosing valve.

Refer to Procedure 011-059

  • Perform the Aftertreatment Diesel Exhaust Fluid System Leak Test found under ECM Diagnostic Tests.

Refer to Procedure 011-080

Specification

  • If a line, fitting, connection, or dosing unit is leaking, then a malfunction has been detected in the aftertreatment diesel exhaust fluid system or dosing unit.

Linked Solutions

  • None

Repair

  • Repair or replace the leaking components.

Refer to Procedure 011-059

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the “Conditions for Clearing the Fault Code” found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00000443

Verification

Conditions

  • Connect all components.
  • Turn keyswitch ON.
  • Connect the recommended Cummins® electronic service tool or equivalent.

Action

  • Use the recommended Cummins® electronic service tool or equivalent to read the fault codes.
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revision listed in the ECM calibration revision history for applicable changes.

Specification

  • If a calibration update for this fault code is available, the ECM calibration revision must be that revision or higher.

Linked Solutions

  • None

Repair

  • Prior to downloading the ECM calibration, check to see that all job images and all other troubleshooting has been documented as downloading an ECM calibration will remove the fault codes on the ECM.
  • Download the updated ECM calibration code.

Refer to Procedure 019-032

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the “Conditions for Clearing the Fault Code” found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

If all steps have been completed and no root cause has been identified, then follow the technical escalation process.

× How can I help you?