Overview
CODE | REASON | EFFECT |
Fault Code: 3717 PID: SPN: 3226 FMI: 13/13 LAMP: Amber SRT: |
A nominal system voltage mismatch has been detected by the aftertreatment outlet NOx sensor.
|
None on performance. |
Circuit Description
The aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.
Component Location
The aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.
Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.
Conditions for Setting the Fault Codes
The Engine Control Module (ECM) detected a mismatch between the engine’s electrical system voltage and the NOx sensor voltage rating.
Action Taken When the Fault Code is Active
- The ECM illuminates the amber CHECK ENGINE lamp and/or the malfunction indicator lamp (MIL) immediately when the diagnostic runs and fails.
Conditions for Clearing the Fault Code
- To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.
- The fault code status displayed by the recommended Cummins® electronic service tool or equivalent will change to INACTIVE immediately after the diagnostic runs and passes.
- The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
- For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
- The “Reset All Faults” command in the recommended Cummins® electronic service tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop Talk
Possible causes of this fault code include:
Calibration incompatibility between aftertreatment outlet NOx sensor and ECM calibration
System voltage incorrect for installed aftertreatment outlet NOx sensor part number.
Incorrect aftertreatment outlet NOx sensor is installed in exhaust system.
- Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.
For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.
Troubleshooting Summary
Solution: S00000886
Verification
Conditions
- Turn keyswitch ON.
- Connect the recommended Cummins® electronic service tool or equivalent.
Action
- Verify the Electrical System Voltage setting is correct for the engine configuration with the recommended Cummins® electronic service tool or equivalent.
Specification
- If the Electrical System Voltage setting does not match the measured voltage, then the incorrect adjustable parameter is configured.
Linked Solutions
- None
Repair
- Use the recommended Cummins® electronic service tool or equivalent.
- Configure the electrical system voltage to match the engine configuration.
Validation
- Connect all components
- Connect the recommended Cummins® electronic service tool or equivalent.
- Disable the fault code.
- Operate the engine within the “Conditions for Clearing the Fault Code” found in the Overview section of the troubleshooting procedure.
- Verify that the fault code is no longer active.
- Check ECM Calibration Revision History
- Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
- Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
- Refer to ECM Calibration Revision History Database.
Solution: S00002877
Verification
Conditions
- Turn keyswitch OFF.
Action
- Verify the correct aftertreatment outlet NOx sensor is installed for engine configuration (12 or 24 volt).
- Turn keyswitch ON.
- Connect the recommended Cummins® electronic service tool or equivalent.
- Use the recommended Cummins® electronic service tool or equivalent to read the fault codes.
Specification
- If the aftertreatment outlet NOx sensor is not the correct sensor part number for the engine configuration, then the incorrect sensor has been installed.
- If the fault code is active or inactive and has more than one inactive count within the last 25 engine operating hours, then a malfunctioning aftertreatment outlet NOx sensor has been detected.
Linked Solutions
- None
Validation
- Connect all components
- Connect the recommended Cummins® electronic service tool or equivalent.
- Disable the fault code.
- Operate the engine within the “Conditions for Clearing the Fault Code” found in the Overview section of the troubleshooting procedure.
- Verify that the fault code is no longer active.
- Check ECM Calibration Revision History
- Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
- Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
- Refer to ECM Calibration Revision History Database.
Solution: S00000443
Verification
Conditions
- Connect all components.
- Turn keyswitch ON.
- Connect the recommended Cummins® electronic service tool or equivalent.
Action
- Use the recommended Cummins® electronic service tool or equivalent to read the fault codes.
- Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
- Compare the ECM code and revision number in the ECM to the calibration revision listed in the ECM calibration revision history for applicable changes.
Specification
- If a calibration update for this fault code is available, the ECM calibration revision must be that revision or higher.
Linked Solutions
- None
Repair
- Prior to downloading the ECM calibration, check to see that all job images and all other troubleshooting has been documented as downloading an ECM calibration will remove the fault codes on the ECM.
- Download the updated ECM calibration code.
Validation
- Connect all components
- Connect the recommended Cummins® electronic service tool or equivalent.
- Disable the fault code.
- Operate the engine within the “Conditions for Clearing the Fault Code” found in the Overview section of the troubleshooting procedure.
- Verify that the fault code is no longer active.
- Check ECM Calibration Revision History
- Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
- Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
- Refer to ECM Calibration Revision History Database.
If all steps have been completed and no root cause has been identified, then follow the technical escalation process.